Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
CavoFerroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavo

Bus Cavo

Serracavi

Data Cable

Calore di rilevamento Cavo
Cavo ad alta temperatura
Cavo autostrada
Marine, petrolio, gas e petrolchimico Cavo
Cavo Speciali
Cavo a spirale
Termocoppia Cavo
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Cavo telefonico

 VDE Order Code

A-BCDEFG HxI…JKLMN

A Basic Types

A- - Outdoor telephone cables
S- - Switchboard cables
J- - Installation cables
JE- - Fire Alarm cables
AJ- - Outdoor cable with protection against inductive
        influences
T- - Terminating cable

B Insulation Types

02Y - Cellular PE
2Y - Solid PE
02YS - Foam Skin Insulating cover of cellular PE with
           additional skin of solid polyolefine.
Y - PVC
H - LSZH

C Filling

F - Petroleum jelly filling
Blank - Unfilled

D Screening Material

(St) - Static shield of plastic-backed aluminum Tape           for indoor cables
D - Shield of copper wire whipping over one        stranding element (e.g. pair)
LR - Corrugated alumnium tape
Blank - No screen

E Bedding Material

2Y - PE
Y - PVC
H - LSZH
M - Lead Sheath
MZ - Special Alloyed Lead Sheath
Blank - No Bedding

F Armouring Material

b - Armouring
SR - Corrugated steel tape
T - Messenger of galvanized steel wires.
Blank - No Armour

G Sheath Material

2Y - PE
Y - PVC
H - LSZH

(L)2Y - Laminated sheath (shield of PE coated             aluminium tape bonded with PE sheath).
M - Lead Sheath
MZ - Special Alloyed Lead Sheath
Blank - No Sheath

H Number of Pairs/Quads

2x2 - 2 Pairs
2x4 - 2 Quads

I Conductor Size

0.4 - 0.4mm
0.5 - 0.5mm
0.6 - 0.6mm
0.8 - 0.8mm
0.9 - 0.9mm

J Stranding Element

PiC - Pairs shielded with copper braid
PiMF - Pairs shielded with aluminium/polyester tape
St - Star Quad(Phantom)
StI - Star Quad(trunk cable)
StIII - Star Quad (local cable)
TIC - Triple shielded with copper braid
TiMF - Triple shielded with aluminium/polyester tape

K Cable Type

S - Railway signaling cable

L Types of Stranding

Lg - Stranded in layers
Bd - Unit Type stranding

M Copper/Steel Tape/Braid Screen Options

(…Cu) - Total cross section of copper shield in mm sq
(fK) - Longitdinally applied copper tape, supplement to (St)
2B…- two layers of steel tape, thickness of steel tape in mm

N Fire Resistance Options

E30 - 30mins circuit integrity according to DIN VDE 4102 Part 12
E60 - 60mins circuit integrity according to DIN VDE 4102 Part 12
F180 - 950°C 180mins Insulation integrity according to IEC 60331&VDE 0427-814

For Example:

Outdoor Telephone Cables

A-2YF(L)2Y…25X2X0.4 StIII Bd

Outdoor telephone cable, solid PE insulated, jelly filled, PE coated aluminium tape bonded with PE sheath, star quad & unit stranding, 25 Pairs 0.4mm to VDE 0816/DIN57816

A-2Y(L)2Y…25X2X0.4 StIII Bd

Outdoor telephone cable, solid PE insulated, PE coated aluminium tape bonded with PE sheath, star quad & unit stranding, 25 Pairs 0.4mm to VDE 0816

A-02YF(L)2Y…25X2X0.6 StIII Bd

Outdoor telephone cable, Cellular PE insulated, jelly filled, PE coated aluminium tape bonded with PE sheath, star quad & unit stranding, 25 Pairs 0.6mm to VDE 0816

A-02YSF(L)2YB2Y…25x2x0.6 StIII Bd

Outdoor telephone cable, foam skin insulated, jelly filled, PE coated aluminium tape bonded with PE sheath, double galvanized steel tape armoured, star quad & unit stranding, PE oversheathed, 25 Pairs 0.6mm to VDE 0816

Indoor Telephone Cables

J-Y(St)Y…10X2X0.6 Lg

Installation cable, PVC Insulated, static shield of plastic backed aluminium Tape, PVC Sheathed, stranded in layers, 10 pairs 0.6mm to VDE 0815

J-2Y(St)Y…10X2X0.4 StIII Bd

Installation cable, solid PE Insulated, static shield of plastic backed aluminium Tape, PVC Sheathed, star quad and unit stranding 10 pairs 0.4mm to VDE 0815/0816

J-YY… 10X2X0.6 Bd

Installation cable, PVC Insulated, PVC Sheathed, star quad and unit stranding 10 pairs 0.6mm to VDE 0815/DIN 57815

Outdoor Telephone Cables with protection against
inductive influences.

AJ-2Y(St)YbY…10X4X1.4 S Lg (fK) (2B 0.5)

Outdoor Telephone Cable for railway signaling - Solid
PE Insulated, aluminium tape shielded, PVC sheathed, stranded in layers, copper tape with two layers of steel tape of 0.5mm, 10 Quads 1.4mm

AJ-2YDYbY…7X4X1.4 S Lg (25…Cu/2B 0.5)

Outdoor Telephone Cable for railway signaling - Solid PE Insulated, copper wire shielded, PVC sheathed, stranded in layers, 1.2mm copper wire shield cross section 25mmsq, with two layers of steel tape of 0.5mm, 7 Quads 1.4mm